Two-Piece Ductile Iron Repair Clamp (UU)

Repair a local pipe leak with a two-piece clamp. The split cast body assembles around the pipe. Select against the measured pipe OD, damage extent and required assembly length.

Pipe compatibility
Confirm the pipe material at the repair location. A ductile iron clamp body does not define the compatible pipe materials.

Product overview

Repair a local pipe leak with a two-piece clamp.

Pipe compatibility

Confirm the pipe material at the repair location. A ductile iron clamp body does not define the compatible pipe materials.

Connection arrangement

Clamp around the pipe at the repair location

Request a Quote

How the repair assembly works

Split assembly

The two-piece cast body is assembled around the pipe. Use the exact UU drawing for the selected size.

Seal and fasteners

Confirm the seal and fastener configuration for the operating conditions and the selected clamp.

Repair coverage

Measure the pipe OD and describe the damage extent. Request the current drawing and installation document for the required assembly length.

Request a Quote

Catalogue dimensions

Catalogue reference dimensions from the AQUAFITTING source drawing currently shown on this page. Confirm the selected configuration and current dimensions before ordering.

Two-Piece Ductile Iron Repair Clamp (UU) — Catalogue dimensions
DNPipe OD (mm)L (mm)B (mm)
8088-99225219
100107-119225246
150157-171225291
200219-226310352
250270-276310420
300320-328310471

Technical evidence

Review the product identity and available resources, then send the required size or measured outside diameter, pipe material, connection details, operating conditions, quantity, destination and supporting files.

Technical Downloads

Universal dual clamp

Universal dual clamp

Product FAQs

What does UU identify?

UU identifies the AQUAFITTING Two-Piece Ductile Iron Repair Clamp in the Pipe Repair Solutions range.

What information is needed for UU selection?

Send the pipe material, measured outside diameter, condition, repair location and operating requirements.

Which UU documents should I request?

Request the current product sheet, dimension drawing and installation document for the exact UU size under review.

Product selection

product name; pipe outside diameter; pipe material; repair or damage condition; repair length if applicable; working pressure; quantity; destination

Request a Quote

Two-Piece Ductile Iron Repair Clamp (UU)

Two-piece ductile iron repair clamp UU product view

Repair a local pipe leak with a two-piece clamp. The split cast body assembles around the pipe. Select against the measured pipe OD, damage extent and required assembly length.

Pipe compatibility
Confirm the pipe material at the repair location. A ductile iron clamp body does not define the compatible pipe materials.

Product summary · PDF · English · V2026.08 · 97 KB

Request a Quote

Overview

Catalogue dimensions

DN
Pipe OD (mm)
L (mm)
B (mm)
80
88-99
225
219
100
107-119
225
246
150
157-171
225
291
200
219-226
310
352
250
270-276
310
420
300
320-328
310
471

Catalogue reference dimensions from the AQUAFITTING source drawing currently shown on this page. Confirm the selected configuration and current dimensions before ordering.

80

Pipe OD (mm): 88-99 · L (mm): 225 · B (mm): 219

100

Pipe OD (mm): 107-119 · L (mm): 225 · B (mm): 246

150

Pipe OD (mm): 157-171 · L (mm): 225 · B (mm): 291

200

Pipe OD (mm): 219-226 · L (mm): 310 · B (mm): 352

250

Pipe OD (mm): 270-276 · L (mm): 310 · B (mm): 420

300

Pipe OD (mm): 320-328 · L (mm): 310 · B (mm): 471

Product overview

Repair a local pipe leak with a two-piece clamp.

Pipe compatibility

Confirm the pipe material at the repair location. A ductile iron clamp body does not define the compatible pipe materials.

Connection arrangement

Clamp around the pipe at the repair location

Request a Quote

Technical evidence

Review the product identity and available resources, then send the required size or measured outside diameter, pipe material, connection details, operating conditions, quantity, destination and supporting files.

Technical drawing for AQUAFITTING Two-Piece Ductile Iron Repair Clamp (UU).
Dimension table for AQUAFITTING Two-Piece Ductile Iron Repair Clamp (UU).

How the repair assembly works

Split assembly

The two-piece cast body is assembled around the pipe. Use the exact UU drawing for the selected size.

Seal and fasteners

Confirm the seal and fastener configuration for the operating conditions and the selected clamp.

Repair coverage

Measure the pipe OD and describe the damage extent. Request the current drawing and installation document for the required assembly length.

Request a Quote

Product selection

product name; pipe outside diameter; pipe material; repair or damage condition; repair length if applicable; working pressure; quantity; destination

Request a Quote

Product FAQs

What does UU identify?

UU identifies the AQUAFITTING Two-Piece Ductile Iron Repair Clamp in the Pipe Repair Solutions range.

What information is needed for UU selection?

Send the pipe material, measured outside diameter, condition, repair location and operating requirements.

Which UU documents should I request?

Request the current product sheet, dimension drawing and installation document for the exact UU size under review.

Technical Downloads

VERIFIED PRODUCT VIDEO Product videos appear only when the exact product identity has been confirmed. Use the product sheet and technical enquiry route for selection.

3 pieces collar with Flange Outlet

3 pieces collar with Flange Outlet

Pipe Repair Solutions

Three-piece ductile iron collar with a separately sized flanged outlet.

3 pieces collar

3 pieces collar

Pipe Repair Solutions

Three-piece ductile iron collar for pipe-repair applications.

Split Collar for PVC and PE pipes

Split Collar for PVC and PE pipes

Pipe Repair Solutions

Split-body mechanical pipe connection and repair coupling for PE/PVC pipes.

bottom of page